> On 15 Oct 98 at 8:36, Matthias Mansfeld wrote:
>
> > (snip snap)
> ... but the CAM SW should do this not silently but should say what is
> illegal and give a report what hes to changed.
> If the prototype manufacturer "repairs" and plots these files well,
> then the customer might think "everything OK" and will fall on his
> nose with the same data at the mass production manufacturer. I know
> this problem well because I had a similar problem with a half-wrong
> Sieb & Meyer drill data output which would run well on the one CAM
> software and would produce wrong drill hits on the other CAM
> software!

In the new company for which I work (We are a flex circuit design and
panelization service bureau) we will call our customers who send us data
that is incorrect.  However, many manufacturers do not communicate back to
their customer because they are afraid that they will be viewed as "hard to
do business with".  When I call a designer who has given me incorrect or
poor data, I typically get the answer "None of our other vendors had
problems with our data".  If we are all to improve it is important that we
be able to freely communicate back and forth regarding data without being
viewed as difficult.

> On 15 Oct 98 at 8:36, Matthias Mansfeld wrote:
>
> > (snip snap)
> I assume that a CAM software sold as OEM software from Gerber
> Systems directly could be considered as "gold standard" for
> correct gerber files.

Although it should be, this is not necessarily true.  The software that
Gerber Systems sells was not developed by Gerber.  I don't know who it is
today, but it used to be VALOR.  The true test is the plotters
interpretation of the data.

Dave Roesler
TRI-C Design, Inc.

################################################################
DesignerCouncil E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE DesignerCouncil <your full name>
To unsubscribe:   SIGNOFF DesignerCouncil 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2