What methods are available to measure flux deposition/amount? Is
there a target amount that will yield acceptable results from a
In Circuit Test and cleanliness standpoint?
What is the best method to monitor cleanliness in a no-clean
process?
______________________________ Reply Separator _________________________________
Subject: Re: No-clean Process Controls
Author: [log in to unmask] at SMTPLINK
Date: 7/6/95 10:12
Mr. Li,
Could you be more specific in your question? I have been closely involved in
all of the phases of the Cleaning and Cleanliness Test Program. What aspect
of control are you interested in: flux amount, handling, etc? I wrote the
majority of the text for TR-582, so if you could contact me, I could explain
further.
Douglas Pauls
Contamination Studies Laboratories
[log in to unmask]
Phone: 317-457-8095
|
|
|