If the problem you have is ingress or retention of moisture (and associated
ionics) then no semi-aqueous process is going to be satisfactory as these
involve a water rinse. Some of the glycolether products aka oxygenated alcohols
- Prozone Dowanol Zestron etc- can be used solvent/solvent instead of
solvent/water, in addition some people use isopropanol instead of water. You
would have to take account of the flammability of the IPA before going down this
route.
Mike Fenner
Bonding Services UK
[log in to unmask]
--------------------------------------
We are currently using Duriod 6002/6010 type PWB's on one of
our products and are having problems cleaning the PWB's
after soldering and assembly operations. Removal of fluxes
and the cleaning fluid (Axarel) from this very hygroscopic
material has been difficult inspite of using the
Manufacturers recommended process. Any information
or sources of potential information relating to resolving
this situation would be appreciated.
[log in to unmask]
|
|
|