Techneters,
I have another tricky question.
We see separation at the Cu pad/laminate interface. The area is rather small (20 microns in section), BUT it's located at the periphery of BGA pads.
My concern is that the separation will act as a stress concentrator causing pad cratering, once the BGA is placed.
I'm positive it's a real scenario, as we investigated a similar case over a year ago.
According to 6012C the board is acceptable (at least from my understanding).
The question is: Is there a way to legitimately reject the board?
Regards,
Vladimir
SENTEC Testing Laboratory Inc.
11 Canadian Road, Unit 7.
Scarborough, ON M1R 5G1
Tel: (647) 495-8727
Cell: (416) 899-1882