Hi Graham,

we are ambivalent as to LGAs and are therefore  testing just now. We have 
passed 10,000 cycles -40/+60 Celsius and got some indications from the daisy 
chains that there is something going on.Sonoscan shows some interrupts but 
we have not found out where yet. This very day I got a emergency call from a 
guy about LGAs. I don't have many details yet, but the issue is scaring: the 
LGAs have pushpulled so violently in the copper traces, that the copper has 
lifted from the board!! I'll be back with more details next week This was a 
MIL microwave board and the LGAs had just some 20 I/Os.  Why he used them? 
Because they are superior in all means to BGAs at 30-100 GHz.

Inge



----- Original Message ----- 
From: "Graham Collins" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, April 16, 2009 12:32 PM
Subject: [TN] LGAs in a military environment?


Hello Technet!
One of our designers is advocating using a LGA component in a military
product.  Anyone out there doing it?  I'm wondering (worried) about the
reliability since it has a very low standoff.  And cleaning issues?

An example of the parts I'm referring to:
http://www.linear.com/designtools/packaging/lga/05081807_a_lga66.pdf
A Linear Technologies p/n LTM4604

regards,

Graham Collins
Halifax Production Engineering
(902) 873-2000 ext. 6215


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2