I will suggest a conductive via fill in these areas to provide a flat
SMT site, because - solder joint could be starved by flow down into the
via. Also Sm plugged on the opposite side will also cause excessive
voiding as the capped via will provide a good outgassing effect during
relow. Not the cheapest solution but is effective in hiding vias in
pad.
Jeffrey Bush
Director, Quality Assurance and Technical Support
76 Technology Drive - POB 1890
Brattleboro, Vermont 05302-1890
Tel. 802.257.4571.21 Fax. 802.257.0011
[log in to unmask]
http://www.vtcircuits.com
-----Original Message-----
From: Tom Parkinson [mailto:[log in to unmask]]
Sent: Friday, June 25, 2004 11:14 AM
To: [log in to unmask]
Subject: [TN] VIA in Pad
We're a CM. One of our customers is asking us to build a board assembly
that will be using BGAs with VIAs in pads. They are in the design
stages at this point, and we have some concerns with having a Via in the
middle of a BGA pad. Anyone have suggestions and/or experience with
this??
Thanks
Tom Parkinson - Quality System Manager - CIT
WinTronics, Inc.
Ph: 724-981-5770 Ext. 235
Fax: 724-981-1772
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|