On Fri, 14 Aug 1998, Dhawan, Ashok wrote:
> 1.How many are using immersion gold with barrier under-plating as
> process. What is process spec for finish as immersion gold--I mean
> barrier plating and gold coating.
Electroless nickel of 150~200 microinches is always the barrier between
copper and immersion gold (3~6 microinches). Electroless nickel sould be
100 minimum, another 50 to ensure good performance. Immersion gold is
self limiting up to ~8 microinches.
> 2. If there is a board manufacturer(s), what is trend or percentage of
> users on gold immersion?
Probably 20 % of overall products.
> 3. Anybody like to share the good or bad experience on technet. Can you
> recommend any board manu with good experience on large volume, long time
> troublefree supply of immersion gold finish.
Try Dynamic Circuits Inc in Milpitas, CA. (1831 Tarob Court, Milpitas,
CA95035, 408-263-0940)
> 4. What is advise on electroless vs eletrolytic or anything else wrt
> phosphorus??
Electroless nickel has about 8% of
phosphorus. I donot see the phosphorus content matters a lot. you might
prefer a certain percent of P according to your abssemble requirement.
Technet had this disscussion before but i don't quite remember.
> 5. What are the things I should check while going in for it.
process controll of the line, defect history, SPC of plating thickness,
compatibility of solder mask, etc.
> >
> >
> > Ashok Dhawan P.ENG.
> > Manufacturing Engineering
> > Unisys Canada Inc.
> > 51 Burmac Road
> > Winnipeg R2J4C9
> > CANADA
> > Fone 204-257-9199
> > Fax 204-257-9104
> >
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|
|
|