Hi Bryan,
I'm Curious as to what Class copper you are using on the Inner layers. We have
found that in the past that class-1 copper would not cut it, and switched to
Class-3 Copper which is more ductile. This practically eliminated foil
cracking.
Regards,
Les
> From: Bryan Kerr +44 1383 822131 ext 4409 <[log in to unmask]>, on 2/25/99
> 4:58 PM:
> On this subject, I have recently been investigating an open circuit problem
> with a multilayer board and have found a small, but significant, level of
> foil
> cracking at the hole / inner layer interface with no apparent reason. There
> are
> no unused pads and I had already been pondering whether the lack of these
> "dummy" pads could result in more stress on the inner layer junctions during
> thermal shock - 288 C for 10 seconds. Maybe any weaknesses in the junction
> are
> more likely to result in fracture if there are no dummy pads ?
> Comments, anybody.
>
> Bryan
>
> ################################################################
> TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
> ################################################################
> To subscribe/unsubscribe, send a message to [log in to unmask] with following
> text in the body:
> To subscribe: SUBSCRIBE TechNet <your full name>
> To unsubscribe: SIGNOFF TechNet
> ################################################################
> Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section
> for additional information.
> For technical support contact Hugo Scaramuzza at [log in to unmask] or
> 847-509-9700 ext.312
> ################################################################
>
>
|
|
|