IPC-2221 talks to that question, lead diameter to hole size and its
focus is solder joint formation. Sorry, my copy is out on loan. But
connectors can be a little tricky. Some of them rely on the hole help
keep them vertical. Be sure to look at the application notes for the
connector as well.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of West, Jim
Sent: Tuesday, July 22, 2003 4:52 PM
To: [log in to unmask]
Subject: [TN] Hole size Standard for Plated thru-holes


Hi everyone,

Does anyone know of an IPC standard that will tell what a plated
thru-hole size should be depending on the diameter of the component that
will be inserted. Example would be a pin header, or a certain wire size.
Basically, how much bigger do you make the hole to accommodate the size
needed so that you will get a good solder joint, and designed well for
manufacturing.

Thanks,
Jim
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
-----------------------------------------------------



---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------


ATOM RSS1 RSS2