As no-one on the Technet has ever seen a copper content this high before
(there are a lot of experienced people out there) - is it worth checking
your analysis by getting a second opinion - maybe something has gone wrong
somewhere?!?!?
We carry out regular analysis but we rarely have a failure and copper
content has never been an issue even on an old roller tinner in our PCB
plant (it obviously sees nothing but bare copper) so it seems as if
something is wrong somewhere!
Neil Atkinson - Quality Manager
Stadium Electronic Controls Division
Stephen House, Brenda Road, Hartlepool TS25 2BQ (UK)
-----Original Message-----
From: Phil Nutting [mailto:[log in to unmask]]
Sent: 15 August 2001 15:18
Subject: Re: Solder analysis results
Wow, The overwhelming solution is to lower the pot
temperature and skim
it off the top. This will have to be a project for an
up-coming weekend
or evening.
I think somebody asked how long it has been since our last
analysis or
did we drop pennies into the pot. The truth is (hanging
head in shame)
we have been running the machine for 5 years and this is the
first
analysis we have performed... to quote Steve Gregory -
Woooo-doggies!
With age we all get smarter and I've just been enlightened.
Thanks to all of you for your responses.
Phil Nutting
-----Original Message-----
From: Lou Hart [mailto:[log in to unmask]]
Sent: Wednesday, August 15, 2001 9:21 AM
To: [log in to unmask]
Subject: Re: [TN] Solder analysis results
Any comment on Steve's stratification theory? A few years
back I had
SPC
charts at a HASL pot at a PC fab, with analysis every two
weeks. Cu
content stayed 0.21% to 0.24% over a period of 1+ years,
even though all
we
were doing was skimming stuff off the top. Lou Hart
-----Original Message-----
From: Stephen R. Gregory [SMTP:[log in to unmask]]
Sent: Tuesday, August 14, 2001 10:04 PM
To: [log in to unmask]
Subject: Re: [TN] Solder analysis results
Dave,
Surely, not ALL 1700-lbs.? Wooo-doggies! I can only imagine
what a task
that
would be!!! I've read some stuff that if you keep the pot
static, and
keep
it
at a stable temperature for a period (what this really is, I
don't
know...there's varying opinions), the metals will seek their
own level
(according to the different opinions, the copper will be
towards the
top),
then you scoop out out the top layer, and replenish what
you've removed
with
fresh bars.
The question that I have though, how did the pot get so out
of balance
with
copper? I've never had a problem with copper content, even
when waving
OSP
boards...tin levels dropping, yes. But not excessive
copper...somebody
throw
some pennies in the pot?
-Steve Gregory-
> RJ Klien Wassink suggests [bible p 169] pouring
contaminated solder at
about
> 190°C through a 20 mesh stainless steel stariner to reduce
copper
content
to
> 0.25%.
>
> Dave Fish
>
<< File: ATT00002.htm >>
------------------------------------------------------------------------
---------
Technet Mail List provided as a free service by IPC using
LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with
following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following
message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources
& Databases
> E-mail Archives
Please visit IPC web site
(http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700
ext.5315
------------------------------------------------------------------------
---------
#####################################################################################
Attention:
This message is for the named person's use only. It may contain confidential,
proprietary or legally privileged information. No confidentiality or privilege
is waived or lost by any mistransmission. If you receive this message in error,
please immediately delete it and all copies of it from your system, destroy any
hard copies of it securely and notify the sender. You must not, directly or
indirectly, use, disclose, distribute, print, or copy any part of this message
if you are not the intended recipient. STADIUM GROUP PLC and any of its subsidiaries
each reserve the right to monitor all e-mail communications through its networks.
Any views expressed in this message are those of the individual sender, except where
the message states otherwise and the sender is authorised to state them to be the
views of Stadium Group Plc. or one of its subsidiaries.
Although this message has been scanned by MailMarshall for known viruses and
inappropriate content, we recommend that recipients employ appropriate measures on
their systems to intercept any such material.
Thank You - Stadium Group Plc., IT Department - Tel: +44 (0)1429 266544
#####################################################################################
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|