TECHNET Archives

May 2001

TechNet@IPC.ORG

Options: Use Monospaced Font
Show HTML Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"PERALTA, Kevin (BREA)" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Mon, 21 May 2001 13:59:39 -0400
Content-Type:
multipart/alternative
Parts/Attachments:
text/plain (1949 bytes) , text/html (3088 bytes)
Neda,

Not true at all. Not all pink foam is static shielding, never trust it! Per
the IPC-A-610 document, always, again "ALWAYS" treat your assembly as ESDS.
And, always remember that "TARGET" handling is with ESD Gloves & ground
strap (tested) handling board on the edges. "ACCEPTABLE" is the same, but
without gloves. Anything else is "DEFECT"!

Now, what to do with your so-called engineer. Send him to ESD training,
immediately!!!

Kevin Peralta
TRW Aeronautical

-----Original Message-----
From: Neda Thrash [mailto:[log in to unmask]]
Sent: Monday, May 21, 2001 10:31 AM
To: [log in to unmask]
Subject: [TN] ESD Approved Packing Foam vs. Static Shielding Bags


** High Priority **

Hello everyone! I need help settling a dispute. I am aware of the fact that
the pink foam designed for packing esd sensitive assemblies helps eliminate
the possibility of a charge being generated during a transport while
cushioning the product but I have an engineer telling me that the assemblies
are safe if holding  the assembly in hand while ungrounded as long as the
foam separates the hand at the point the pcb is held. If someone knows this
to be true please send me more information on this because this contradicts
what I have always been taught and what I am teaching. I need your help
ASAP!

TIA, Neda

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----


ATOM RSS1 RSS2