Larry,
I've been away on vacation (Yellowstone was awsome) but as an old hybrid
groupie I would add that we used Sn62 for SMT on palladium Ag thick film
conductors for improved leach resistance both of the conductor (especially
when it came to rework) and non-nickel barrier PdAg components.
Regards,
Bruce Misner
> ----------
> From: Larry Koens[SMTP:[log in to unmask]]
> Reply To: TechNet E-Mail Forum.;Larry Koens
> Sent: Wednesday, July 25, 2001 4:10 PM
> To: [log in to unmask]
> Subject: [TN] solder paste with 2% silver
>
> Got a question for everyone,
>
> I just switched companies and the new company that I'm with now uses a
> 62/36/2 solder paste. I've always used the 63/37 formula. The guys who
> decided to use the 2% silver are no longer with the company. My question
> to you is, why would they want the 2% silver in the paste? They know
> something I don't?!
>
> Thanks,
> Larry
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL