TECHNET Archives

April 1997

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0wFP7w-000BjJC; Thu, 10 Apr 97 14:03 CDT
Content-Type:
text/plain; charset="us-ascii"
From [log in to unmask] Fri Apr 11 11:
26:33 1997
Date:
Thu, 10 Apr 1997 15:15:41 -0400
Precedence:
list
Resent-From:
Resent-Sender:
TechNet-request [log in to unmask]
MIME-Version:
1.0
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/11887
TO:
Return-Path:
<TechNet-request>
X-Status:
X-Loop:
Resent-Message-ID:
<"GsQO23.0._DG.sbJJp"@ipc>
Subject:
From:
"Baker,Kelly" <[log in to unmask]>
Old-Return-Path:
Content-Transfer-Encoding:
7bit
X-Mailer:
Microsoft Exchange Server Internet Mail Connector Version 4.0.837.3
Message-ID:
Parts/Attachments:
text/plain (58 lines)


----------
From:  Denis Meloche[SMTP:[log in to unmask]]
Sent:  Thursday, April 10, 1997 2:58 PM
To:  Baker,Kelly
Subject:  Electroless Gold

Dennis,

Thanks for your help, but its immersion gold that were using.  Any 
information that you have for this would be greatly appreciated.

Thanks again,

Kelly



I have specified and used electroless gold platings for mil-std for a 
number
of years. I remember that there were specifications which allowed my
previous employer to waive solder tining requirement if the Au was 
between a
range of thicknesses.  We ended using Au for a number of applications 
where
tinning was impractical.  I don't remember the specification we used. 
 I
still have email access to my old employer and could probably get you 
an
answer in a few days.  I also have the email address for our old DCAS
inspector and he knew the spec # for everything.  If you need any 
soldering
help for Au I have a publication from the international tin institute I
could send you.
Good Luck,
  
Denis Meloche
Technical Sales Engineer
Heraeus Cermalloy Division
24 Union Hill Rd
West Conshohocken Pa., 19428
610-825-6050 Fax 610-825-7061
E-Mail [log in to unmask]


***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]>   *
* with <subject: subscribe/unsubscribe> and no text in the body.          *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2