Multek have a good photoimaged via generation process capability,
Merix/DCI and Hadco are some others with laser (co + YAG) tech.
The ony reason i suggest these 4 is we have found good results for upto
down 3 mil vias(blind)
Hope that helps
--
PARVEZ M.S. PATEL ADDRESS:
GRADUATE STUDENT, APT.#2, 182 Westend Avenue,
SYSTEMS SCIENCE AND INDUSTRIAL ENGG. BINGHAMTON, NY-13905
STATE UNIVERSITY OF NEW YORK, NEW YORK. U.S.A.
BINGHAMTON-NY.
PH:607-779-7215
##############################################################