Hi Steve,
Guess I was not clear enough. When I said "GOOD to BAD (depending on severity
of operational T-cycles)—partially filled vias, particularly with the
transition from fill to no-fill near the PCB center (stress concentration)",
I meant PCB center in the thickness direction, not edge vs. middle——so relax
in this regard.
In regards your question about what to do:
(1) given your described application, I do not see a reliability issue;
(2) I would advise the customer laying out the scenario that 001 can be
interpreted either way andthat there is no real tachnicalissue; I would hope
the customer is reasonable and appreciates your forthrightness rather than
you trying to pull a fast one;
(3) you may want to provide your customer with a copy of the exchange on the
TN.
Good luck
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 904-437-8747, Fax: 904-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################
|
|
|