Can be done as you said Hans ; but the cost of it is very much in custom
field .
Ivan, I have recently a parallel problem :
where we have a hard rosin no clean flux ;
(yes the test probes to test pads , not solder pads) ;
and do validate because of parallel (stencil) process another no clean with
soft rosin (probe pins through)
My problem is it's so sticky in cool state I worry about SIR within the 3
year warranty on dust and moisture build ups in different working
environments , and therefore trying to keep the hard rosin in place .
Just a thing to consider
Paul Klasek
http://www.resmed.com
-----Original Message-----
From: Hinners Hans CIV WRALC/LYPME [mailto:[log in to unmask]]
Sent: Tuesday, 27 July 1999 6:32
To: [log in to unmask]
Subject: Re: [TN] No clean flux residue
Hi Ivan and All,
As you have discovered there really isn't a 'no clean' flux (at least with
'special' cases, yours - Probe; mine - Conformal Coating). Somebody correct
me if I'm wrong but you have a couple of choices - clean the probes, clean
the boards, or change the equipment/process (i.e.. change the way you test
and/or solder $$$).
The question I have for the group: Would soldering in an inert environment
remove the need for flux all together? I would swear I have seen that
mentioned somewhere recently (where o where? - was it PC FAB or maybe
Precision Cleaning).
Hans
Air Force Material Command - We keep them flying!
~~~~~~~~
Hans M. Hinners WR-ALC/LYPME Bldg. 640
Materials Engineer 380 Second Street,
Suite 104
Manufacturing Eng. Sec. Robins AFB GA 31098-1638
912-926-1970 (Voice) 468 - 1970 (DSN) 912-926-7974 (Fax)
[log in to unmask]
> Hello Technetters:
> Being new to the list, I do not know if this issue has been discussed in
> the
> past, so here goes. What can be done to minimize/eliminate the residue
> left by
> the no clean fluxes on the PCB's? We currently have a big issue with
> residue not
> allowing our test pin probes to make contact. We have implemented cleaning
> the
> probes on a regular basis, but I want to eliminate the issue altogether.
> If this
> has been discussed, please point me in the right direction (archived
> responses).
> If not, I would really appreciate your help.
> Ivan Barrios
> Process Engineer
> Conexant Systems
> El Paso, TX,
>
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following
text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Gayatri Sardeshpande at [log in to unmask] or
847-509-9700 ext.5365
##############################################################
|
|
|