Steve,
In running my DOE I didn't vary mesh size or metal percentage. They
were held fixed for other considerations. I also used commercially
formulated pastes, however in talking to vendors who's pastes performed
the worst I found they were using high temp solvents in their fluxes.
Jim
>-----Original Message-----
>From: Stephen R. Gregory [SMTP:[log in to unmask]]
>Sent: Thursday, October 08, 1998 8:15 AM
>To: [log in to unmask]
>Subject: Re: [TN] Voiding in BGA
>
>In a message dated 10/8/98 6:00:43 AM Pacific Daylight Time,
>[log in to unmask] writes:
>
><< Rod/Bill
> I concur with those numbers as a worst case. Actually 20% max (5 - 10%
> nom) can be pretty easily achieved with the correct thermal profiles and
> the correct paste selection. Boiling point of the paste volatiles plays
> a large part.
> Jim Kittel >>
>
>Hi Jim!
>
> Can I ask what's desireable? Lower boiling point temperatures? Also,
>does
>mesh size and/or percentage of metals in your paste play any role? Thanks!
>
>-Steve Gregory-
>
>################################################################
>TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
>################################################################
>To subscribe/unsubscribe, send a message to [log in to unmask] with following
>text in the body:
>To subscribe: SUBSCRIBE TechNet <your full name>
>To unsubscribe: SIGNOFF TechNet
>################################################################
>Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section
>for additional information.
>For technical support contact Hugo Scaramuzza at [log in to unmask] or
>847-509-9700 ext.312
>################################################################
>
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################
|
|
|