TECHNET Archives

August 1998

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 14 Aug 1998 10:00:36 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (44 lines)
Technet,

After recieving a copy of the Jedec Standard, J-STD-020, I have a question
that hopefully one of you might answer. The Convection Reflow profile
requirement is listed as:

Ramp up rate: +6 degrees C/sec. max
Temperature maintained at 125 degrees C (+/-25): 120 seconds maximum
Temperature maintained above 183 degrees C: 120 - 180 seconds
Time at maximum temperature: 10 - 40 degrees C
Maximum temperature: 220 degrees C (+5/-0)
Ramp down rate -6 degrees C/sec max

My question is when figuring the time maintained at 125 degrees should one
only be counting the time actually maintained at 125 degrees or should I
include time between 100 and 150 degrees C?

Thanks,

Brian



ETS, LLC - West                      ETS, Inc. - East
3939 N. Freya St.                    PO Box 47887
Spokane, WA 99207                    Plymouth, MN 55447
509-483-0900 (voice)                 612-553-0051 (voice)
509-483-0331 (fax)                   612-553-0246 (fax)
[log in to unmask]                        [log in to unmask]

Benefit from a direct relationship with the manufacturer!

################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe:   SUBSCRIBE TechNet <your full name>
To unsubscribe:   SIGNOFF TechNet 
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################


ATOM RSS1 RSS2