We are manufacturing Class 2 PWAs that are not being delivered to
Telcos or RBOCs. We have found nothing in IPC specifications
regarding the following.
Question: When attaching three components for which there are no
solderable pads, is it acceptable to use RTV to "goop the heck"
(official technical term) out of the repair?
What is a more acceptable method?
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC's web site (http://www.ipc.org) "On-Line Services" section for additional information.
For technical support contact Hugo Scaramuzza at [log in to unmask] or 847-509-9700 ext.312
################################################################