Gregg,
Use another board house! Any competent CAD operator at the board house
should have caught the fact you had no power plane connections. I
recommend finding a board house you can rely on to help you achieve a
successful PWB.
Steve Hawn
Precision Digital Images
Gregg Klawson wrote:
>
> We just had a couple of PWB types built incorrectly due to bad electronic
> data being sent to our board houses. Unfortunately we did not catch either
> problem until we had fully assembled the boards.
>
> Problem A was due to the wrong aperture file being sent out resulting in no
> power plane connections. Problem B was due to an old design tool which
> did not show a "filled in" power plane which was required. No netlist data
> was available for either design.
>
> We would like to continue with an all electronic process but need some
> fool-proof checks that will detect if we send some incorrect file(s)/data
> or our board house does something wrong. I'm sure companies are doing this
> sucessfully all the time (and all electronic). How are people making this
> process work well for them?
> ---
> Gregg Klawson
> GTE Government Systems Corp, Taunton, Massachusetts, USA
> [log in to unmask], telephone +1.508.880.1822
>
> The views expressed are the author's and do not necessarily reflect the
> official position of GTE or any of its subsidiaries.
################################################################
TechNet E-Mail Forum provided as a free service by IPC using LISTSERV 1.8c
################################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in the body:
To subscribe: SUBSCRIBE TechNet <your full name>
To unsubscribe: SIGNOFF TechNet
################################################################
Please visit IPC web site (http://jefry.ipc.org/forum.htm) for additional information.
For the technical support contact Dmitriy Sklyar at [log in to unmask] or 847-509-9700 ext.311
################################################################
|
|
|