by ipc.org (Smail3.1.28.1 #2) id m0vkN57-0000ZZC; Tue, 14 Jan 97 22:36 CST from simon.ipc.org by ipc.org with smtp (Smail3.1.28.1 #2) id m0vkMNO-0000UjC; Tue, 14 Jan 97 21:50 CST from emout19.mail.aol.com by simon.ipc.org via ESMTP (940816.SGI.8.6.9/940406.SGI) for <[log in to unmask]> id VAA03418; Tue, 14 Jan 1997 21:51:57 -0800 (from root@localhost) by emout19.mail.aol.com (8.7.6/8.7.3/AOL-2.0.0) id XAA02672 for [log in to unmask]; Tue, 14 Jan 1997 23:00:14 -0500 (EST)
From [log in to unmask] Wed Jan 15 15:
02:52 1997
TO:
Date:
Tue, 14 Jan 1997 23:00:14 -0500 (EST)
Subject:
From:
Status:
O
X-Status:
Message-ID:
Return-Path:
<TechNet-request>
Parts/Attachments:
text/plain (21 lines)
ICT, a 24-hour burn-in, and a functional test after burn-in would typically
not show you a fractured solder joint, because solder joint failures are
almost always intermittent and only show up when disturbed mechanically
(vibration) or thermally (heating or cooling). Insufficient solder is also
not your likely problem--I would guess it is inadequate wetting, for whatever
reason. Since you talk about a fine-pitch component, it is likely large;
temperature profiling of large components during reflow has shown them to lag
behind the PWB and smaller components by as much as 20C at peak reflow. Your
solder joint may never have reached temperatures high enough to assure
consistent good wetting.  

Werner Engelmaier
Engelmaier Associates, Inc.
Electronic Packaging, Interconnection and Reliability Consulting
23 Gunther Street
Mendham, NJ  07945  USA
Phone & Fax: 201-543-2747
E-mail: [log in to unmask]