On Wed, 21 Feb 1996, Steve Quinn wrote:
> We are wondering what is the latest rev of this spec(IPC-A-600D).
> We have one dated 9-25-89. Specifically we are questioning allowable
> plating voids in through holes. Are circumferential voids acceptable in
> current spec?
>
The latest revision of the IPC-A-600 is revision E which was published
August 1995. Circumferential voids in excess of 90degrees are
nonconforming for all three classes in the copper plating section.
****************************************************
Jon Holmen
Technical Project Manager
IPC
2215 Sanders Road
Northbrook IL 60062-6135
Phone (847) 509-9700 ex329
Fax (847) 509-9798
e-mail [log in to unmask]
URL:http://www.ipc.org
*****************************************************
|
|
|