2.4.22 is only for bare (unpopulated) PWB’s, and the rigid portion of rigid-flex PWB's. Section 1 (Scope) explicitly excludes PCBA’s from being evaluated using this method.





José (Joey) Ríos, Sr QA Engineer

Mission Assurance Manager

Kavli Institute for Astrophysics & Space Research

Massachusetts Institute of Technology

[log in to unmask]<mailto:[log in to unmask]>

(617)324-6272









On May 16, 2018, at 7:17 AM, [log in to unmask]<mailto:[log in to unmask]> wrote:



Fellow TechNetters:



  Is there a separate Bow & Twist Test/documentation for Printed Wire Boards, PWB, and Printed Wire Board Assemblies, PWBAs?   Are they interchangeable......