TECHNET Archives

June 2011

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reuven Rokah <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Reuven Rokah <[log in to unmask]>
Date:
Sun, 5 Jun 2011 13:19:52 +0300
Content-Type:
text/plain
Parts/Attachments:
text/plain (81 lines)
Manufacturer should stand behind its own products that passed 4 or 5 (depend
its/customer SOW terms) thermal cycles (rework, reflow or re-balling).

Reuven

On Wed, Jun 1, 2011 at 10:21 PM, Gerald Bogert <
[log in to unmask]> wrote:

> June 1, 2011
>
>
>
> Anyone have technical data to support (or not support) re-balling of
> BGAs to change from SAC balls to Pb balls???
>
>
>
> My understanding is that because of the extra heat cycle involved, BGA
> manufacturers may not stand behind their part warranty if re-balling is
> done.  I also seem to recall a technical poster or paper presented at
> IPC several years ago which I believe indicated a reduction in
> reliability of the part if it is re-balled.
>
>
>
> Also seems to me that if one were to re-ball a BGA, this would be a
> repair and not a reqork process and as such may require specific
> customer approval.
>
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 16.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> For additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>



-- 

Best Regards,

*Reuven Rokah*

Mobile: 972-52-60-120-18
Tele-fax: 97239360688
<http://www.rokah-technologies.com/>[log in to unmask]
[log in to unmask]
www.rokah-technologies.com

**


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2