1.  Change layout
2.  Via cap filling
3.  Plugging from one side only (component side).

Reuven

On Fri, Jun 17, 2011 at 7:59 PM, Richard D. Krug <[log in to unmask]> wrote:

> We've got a customer's PWB that has vias with the barrel either coated with
> solder mask or epoxy filled, then covered with solder mask.  The plugging
> tends to leave a small protrusion above the copper surface.  Some of these
> locations happen to be centered at MELF locations.  During reflow, MELF's
> shift off the high point.
>
> Prevention / mitigation ideas anyone?
>
>
> Dick Krug, SSBB, CSMTPE
> SMT Process Engineer
> Sparton Corporation
> 30167 Power Line Road
> Brooksville, FL  34602-8299
> p (352) 540-4012  (Internal Ext. 2012)
> [log in to unmask]
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 16.0
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> For additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>



-- 

Best Regards,

*Reuven Rokah*

Mobile: 972-52-60-120-18
Tele-fax: 97239360688
<http://www.rokah-technologies.com/>[log in to unmask]
[log in to unmask]
www.rokah-technologies.com

**


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2