At 02:06 PM 12/29/2009, Brooks, Bill wrote:
>What about copper filled vias? I have seen some data on this technology
>where they plate the hole completely shut...
>
>Bill Brooks | Datron World Communications, Inc.
>PCB Designer/Engineer | Office: 760-602-7004| Fax: 760-597-3777 |
>[log in to unmask]
>1808 Aston Avenue, Suite 230, Carlsbad, CA 92008 | www.dtwc.com


You betcha, under the heading of "more annular Cu. :-)  Not too 
widely available yet and is constrained by max via size and aspect 
ratio.  At least one of our main suppliers does quite a bit of it -- 
esp on small buried mechanical drilled vias (saves on need to epoxy 
fill and overplate buried vias to make a suitable target for stacking uVias)

@ Joe Lara,
What via size and board thickness you working with?

dw



>Performance You Require. Value You ExpectTM
>
>
>-----Original Message-----
>From: TechNet [mailto:[log in to unmask]] On Behalf Of Dwight Mattix
>Sent: Tuesday, December 29, 2009 12:29 PM
>To: [log in to unmask]
>Subject: Re: [TN] Thermally Conductive & Plated Via Fill
>
>Practically speaking, using "thermal conductive" and "CB100" in the
>same sentence is an oxymoron.
>
>
>Cu ~= 300 w/mK
>Solder, Ormet, et al ~= 25 w/mk
>CB100 ~=3 w/mK
>
>Small amount more annular copper, filling with Ormet paste (not a
>cheaper option though) or filling via in process with solder yields
>much greater increase in thermal conductivity than CB100.
>
>At 11:55 AM 12/29/2009, Joe Lara wrote:
> >Hello TechNetter's,
> >
> >Im currently using Du Ponts "CB-100" Conductive Paste to vill Vias
> >at $400 per 100G. Is
> >there a more affordable way of filling vias that call out to be
> >filled (thermal conductive) and
> >plated?
> >
> >
> >Best Regards,
> >
> >Joe
> >
> >---------------------------------------------------
> >Technet Mail List provided as a service by IPC using LISTSERV 15.0
> >To unsubscribe, send a message to [log in to unmask] with following text
>in
> >the BODY (NOT the subject field): SIGNOFF Technet
> >To temporarily halt or (re-start) delivery of Technet send e-mail to
> >[log in to unmask]: SET Technet NOMAIL or (MAIL)
> >To receive ONE mailing per day of all the posts: send e-mail to
> >[log in to unmask]: SET Technet Digest
> >Search the archives of previous posts at:
>http://listserv.ipc.org/archives
> >Please visit IPC web site
> >http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> >information, or contact Keach Sasamori at [log in to unmask] or
> >847-615-7100 ext.2815
> >-----------------------------------------------------
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 15.0
>To unsubscribe, send a message to [log in to unmask] with following text
>in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
>[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at:
>http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
>ext.2815
>-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2