That is why you never sleep!  Understood. 

--------------------------

Sent using BlackBerry





----- Original Message -----

From: TechNet <[log in to unmask]>

To: [log in to unmask] <[log in to unmask]>

Sent: Sat Nov 07 17:43:59 2009

Subject: Re: [TN] BGA Balls





 Hi Inge,

I do, I do—but I just was in Casablanca.

Werner



 



 



-----Original Message-----

From: Inge <[log in to unmask]>

To: TechNet E-Mail Forum <[log in to unmask]>; Werner Engelmaier <[log in to unmask]>

Sent: Sat, Nov 7, 2009 6:11 am

Subject: Re: [TN] BGA Balls



















W, do you never sleep? 



/Inge 

 





----- Original Message ----- 

From: "Werner Engelmaier" <[log in to unmask]> 



To: <[log in to unmask]> 



Sent: Saturday, November 07, 2009 11:25 AM 



Subject: Re: [TN] BGA Balls 

 





Hi Gaby, 



This is a loaded question, because of the many 'It depends.' 



There are some BGAs that are thermally asymmetrically designed—particularly 

those with a built-in heat sink. The faster you cool them from soldering the 

more they warp; to some extent, that is also true for PCBs. 



So, who to blame—see above. 



The same mechanism causing your problems is at work with Pb-free soldering 

causing 'pad cratering.' 



Werner 

 



 



 



-----Original Message----- 



From: Gabriela <[log in to unmask]> 



To: 'TechNet E-Mail Forum' <[log in to unmask]>; 'Werner Engelmaier' 

<[log in to unmask]> 



Sent: Sat, Nov 7, 2009 4:16 am 



Subject: RE: [TN] BGA Balls 

 



 



 



 



 





Werner, 



We experienced the failure of corner solder joints sometimes and supposed 



that the trigger was in the mechanical concept of the assembly. 



The reflow process was OK. 



Warping of the BGA or the printed circuit, electrical test stress by probes 



near the corner, connectors near the BGA, were the trigger. 



I thought that the separation of the solder ball occurred on the weakest 



interface, which may have been on the component side. 



Is this a cause for accusing the BGA manufacturer or rather the design of 



the assembly and its use at the field? 



Gaby 

 



-----Original Message----- 



From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier 



Sent: Thursday, November 05, 2009 8:46 PM 



To: [log in to unmask] 



Subject: Re: [TN] BGA Balls 

 



 Hi Bob, 



There is a lot of non-sense put force, and unfortunately, IPC no longer has 



any reliability experts give workshops on reliability at APEXPO 2010. 



Werner 

 



 



 



-----Original Message----- 



From: Robert Kondner <[log in to unmask]> 



To: 'TechNet E-Mail Forum' <[log in to unmask]>; 'Werner Engelmaier' 



<[log in to unmask]> 



Sent: Wed, Nov 4, 2009 5:51 pm 



Subject: RE: [TN] BGA Balls 

 



 



 



 



 





Hi, 

 



 I recall seeing it in the temp specs on the data sheet. It did sound rather 



low for SAC. 

 



 I did not see SAC305 called out, not sure what material it was. I would 



have to go back and double check that data sheet but I swear I saw an above 



217 for xxx seconds. I did see the 250 reccomendation and I did see the 260 



+0 limit. 

 



Bob Kondner 

 



-----Original Message----- 



From: TechNet [mailto:[log in to unmask]] On Behalf Of Werner Engelmaier 



Sent: Wednesday, November 04, 2009 4:53 PM 



To: [log in to unmask] 



Subject: Re: [TN] BGA Balls 

 



 Hi Bob, 



Where do you get "were above the 217 minimum" from? 217 is the Solidus of 



SAC solders-you cannot solder at that temperature because the Liquidus is 



higher than that and alloy dependent. As an absolute minimum for reflow 



[unless vapor phase] you need Liquidus+20C at the slowest heating SJ at the 



BGA center. 



'Verifying conductivity' is insufficient, since the latent defect 



'head-on-pillow' will give you functionality in a test-and, yes, 5 C can 



make the difference. 



Werner 

 



 



 



-----Original Message----- 



From: Robert Kondner <[log in to unmask]> 



To: [log in to unmask] 



Sent: Wed, Nov 4, 2009 11:54 am 



Subject: Re: [TN] BGA Balls 

 



 



 



 



 





Rex, 

 



 Wow, what a you know what contest. :-( 

 



 They complain about a 5C difference at 250C? Hitting 245 is good IMHO, the 



absolute max looks like 260. You were above the 217 minimum. 

 



Do you have any pin test functions like JTAG or ICT to verify joint 



conductivity? Testing for manufacturing defects (MDA) using execution of 



application logic is difficult at best. If they really think there are 



manufacturing defects (opens, short) I would go for something to verify 



connectivity parts. If there are many manufacturing defects then you have a 



process problem. If there are none then it is an application problem. 

 



Bob Kondner 

 



-----Original Message----- 



From: TechNet [mailto:[log in to unmask]] On Behalf Of Rex Waygood 



Sent: Wednesday, November 04, 2009 11:36 AM 



To: [log in to unmask] 



Subject: [TN] BGA Balls 

 



We have built a batch of pcbs for a customer who supplied the pcbs. They 



are 2mm thick 6 layer with 0.2mm vias and ENIG finish. None work fully, 



they work intermittently at best. 

 



The customer was suspicious that we had not reflowed the BGAs correctly. 

 



Our under BGA temp on a similar pcb is 245C (We now have some samples to 



profile correctly) 

 



The customer is suspicious due to the comment on page 753 



http://www.atmel.com/dyn/resources/prod_documents/doc6221.pdf 



<http://www.atmel.com/dyn/resources/prod_documents/doc6221.pdf>  where 



it states a min of 250C 

 



Close x-ray evaluation of the BGAs showed tear dropping along tracks, 



uniform balls, everything looked tickety boo. 

 



We offered to remove a BGA to see what was happening underneath. 

 



2 corners showed a similar issue with the ball where it separated from 



the BGA rather than the pcb. 

 



The removal technique was to use a PDR IR rework station, under board 



heating to bring topside pcb temp to 170C and then a lead free reflow 



profile to bring the device up to reflow, manual removal. 

 



I didn't have dye for dye and pry so thought this might show if there 



was an ENIG problem. 

 



I was surprised by the almost complete removal of ball at the device and 



lack of evidence of solder. 

 



Was this just caused by my investigation processes? 

 



Was the ball device interface broken which prevented it from melting the 



ball? 

 



Any other clues? 

 



Thanks 

 



Rex 

 



 



Hopefully Steve has received the images (sorry about the size!) 

 





Rex Waygood 



Technical Manager 

 



Hansatech EMS provides value manufacturing through engineering and 



quality 

 



________________________________ 

 





Hansatech EMS Limited 



Benson Road 



Nuffield Industrial Estate 



Poole 



Dorset BH17 0RY 



United Kingdom 

 





Tel: 



Fax: 



DDI:    +44 (0)1202 338200 



+44 (0)1202 338202 



+44 (0)1202 338222 



[log in to unmask] 



www.HansatechEMS.com <http://www.hansatechems.com/> 

 





--------------------------------------------------- 



Technet Mail List provided as a service by IPC using LISTSERV 15.0 



To unsubscribe, send a message to [log in to unmask] with following text in 



the BODY (NOT the subject field): SIGNOFF Technet 



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL) 



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest 



Search the archives of previous posts at: http://listserv.ipc.org/archives 



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 



for additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815 



----------------------------------------------------- 

 



--------------------------------------------------- 



Technet Mail List provided as a service by IPC using LISTSERV 15.0 



To unsubscribe, send a message to [log in to unmask] with following text in 



the BODY (NOT the subject field): SIGNOFF Technet 



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL) 



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest 



Search the archives of previous posts at: http://listserv.ipc.org/archives 



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 



for 



additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815 



----------------------------------------------------- 

 



 



 





--------------------------------------------------- 



Technet Mail List provided as a service by IPC using LISTSERV 15.0 



To unsubscribe, send a message to [log in to unmask] with following text in 



the BODY (NOT the subject field): SIGNOFF Technet 



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL) 



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest 



Search the archives of previous posts at: http://listserv.ipc.org/archives 



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 



for additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815 



----------------------------------------------------- 

 



 



 



 



--------------------------------------------------- 



Technet Mail List provided as a service by IPC using LISTSERV 15.0 



To unsubscribe, send a message to [log in to unmask] with following text in 



the BODY (NOT the subject field): SIGNOFF Technet 



To temporarily halt or (re-start) delivery of Technet send e-mail to 



[log in to unmask]: SET Technet NOMAIL or (MAIL) 



To receive ONE mailing per day of all the posts: send e-mail to 



[log in to unmask]: SET Technet Digest 



Search the archives of previous posts at: http://listserv.ipc.org/archives 



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 



for additional information, or contact Keach Sasamori at [log in to unmask] or 



847-615-7100 ext.2815 



----------------------------------------------------- 

 



 



 



 



--------------------------------------------------- 



Technet Mail List provided as a service by IPC using LISTSERV 15.0 



To unsubscribe, send a message to [log in to unmask] with following text in 



the BODY (NOT the subject field): SIGNOFF Technet 



To temporarily halt or (re-start) delivery of Technet send e-mail to 

[log in to unmask]: SET Technet NOMAIL or (MAIL) 



To receive ONE mailing per day of all the posts: send e-mail to 

[log in to unmask]: SET Technet Digest 



Search the archives of previous posts at: http://listserv.ipc.org/archives 



Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 

for additional information, or contact Keach Sasamori at [log in to unmask] or 

847-615-7100 ext.2815 



----------------------------------------------------- 

 







 





---------------------------------------------------

Technet Mail List provided as a service by IPC using LISTSERV 15.0

To unsubscribe, send a message to [log in to unmask] with following text in

the BODY (NOT the subject field): SIGNOFF Technet

To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)

To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest

Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815

-----------------------------------------------------



---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.


ATOM RSS1 RSS2