Our failures were by analysis only.  We did not go into production with these parts. We were evaluating the fatigue reliability of the solder joints.  We tend to be very conservative in our design approach, but we have to be, since we're building hardware that controls the primary power systems in aircraft. We also have generally steered away from QFN parts for the same reasons.

At my former employer we designed a product with QFN microcontrollers. We had a very high percentage of failed solder joints after ESS.  That company's quality systems and ethics were pretty sketchy, so the parts would go through a rework cycle and if they passed ESS after that, the product was shipped.  No cause was assigned, everything was considered an "isolated failure". That product hasn't yet made it to the field (tied to a long development military helicopter program) so the field failure rate is yet to be seen, but it's obviously not going to be good.  Fortunately it's not too critical a piece of hardware.

Gregg


-----Original Message-----
From: kwood716 [mailto:[log in to unmask]] 
Sent: Thursday, April 16, 2009 6:40 AM
To: 'TechNet E-Mail Forum'; Temkin, Gregg
Subject: RE: [TN] LGAs in a military environment?

Gregg,
What were the failures? I'm interested because I see LGA usage picking up
steam here.
Ken



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Temkin, Gregg
Sent: Thursday, April 16, 2009 9:22 AM
To: [log in to unmask]
Subject: Re: [TN] LGAs in a military environment?

We just designed out similar LGAs made by Linear when a reliability analysis
showed VERY EARLY failures probabilities for our typical operation cycle
over a 20 year life.

You can certainly get them soldered and have them pass a screen but that may
not be the whole picture.  Depends on your operating environment/life
requirements.  Suggest having someone who is good at analysis run the
numbers.

Gregg

-----Original Message-----
From: Graham Collins [mailto:[log in to unmask]] 
Sent: Thursday, April 16, 2009 3:32 AM
To: [log in to unmask]
Subject: [TN] LGAs in a military environment?

Hello Technet!
One of our designers is advocating using a LGA component in a military
product.  Anyone out there doing it?  I'm wondering (worried) about the
reliability since it has a very low standoff.  And cleaning issues?

An example of the parts I'm referring to:
http://www.linear.com/designtools/packaging/lga/05081807_a_lga66.pdf
A Linear Technologies p/n LTM4604

regards,
 
Graham Collins
Halifax Production Engineering
(902) 873-2000 ext. 6215


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2