IPC-600-6012 Archives

September 2008

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Mike Hill <[log in to unmask]>
Reply To:
(Combined Forum of D-33a and 7-31a Subcommittees)
Date:
Mon, 8 Sep 2008 15:22:59 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (53 lines)
Pete,

Great question.....and a BIG ONE....

My short answer would be as follows: The existing IPC group that's working
on the "6012 Certification Process for Fabricators" will be answering your
question".  That being said, I'm sure they would invite your inputs.  

However, until this task is completed, there are a lot of similar questions.
Others, feel free to fill in the blanks.

Mike





-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]]On Behalf Of
[log in to unmask]
Sent: Monday, September 08, 2008 1:29 PM
To: [log in to unmask]
Subject: [IPC-600-6012] Quality Conformance Testing IPC-6012 Para. 4.3


All:

IPC 6012 has a requirement for  monthly conformance testing but it does
not state what material should be tested - 

Under the military specifications
(MIL-P-55110/MIL-PRF-31032/MIL-P-50884) a manufacture running both
polyimide and epoxy resins would be required to submit samples of both
material types each month unless the requirement is tailored (31032
allows tailoring).

What is the groups opinion? Should this be addressed in some manner - or
is it addressed and I'm missing it?

Thanks,



Pete Menuez
Supplier Quality Manager
L-3 Communications Cincinnati Electronics
7500 Innovation Way
Mason, Ohio 45040
[log in to unmask]

513-573-6401 Voice
513-573-6767 Fax

ATOM RSS1 RSS2