Ashok,
Looks like you answered your own question.
20 mil pad design - (2.5 mil etch x 2 sides) = 15 mil pad actual > 10
mils
Ben
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ashok Dhawan
Sent: Thursday, May 15, 2008 9:05 PM
To: [log in to unmask]
Subject: [TN] Solder Pad width
I am looking for measured pad width for 20 mil land pattern for SMT.
(QFP or TSOP)
What is Pad width actal versus top copper layer? Copper outer layer is
1 oz or 2 oz or 3 ozs.
Reason for this question: Stencil is 6mils thick with min aperture
opening of 9 mils. For gasketing, the pad need to o=be over 10 mils.
2 Ozs copper has etch factor 2.5 mils over etch each side. Can final pad
width of over 10 mils be made.
Any inputs on this will be appreciated.
Regards
Ashok
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0 To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|