Inge,
I don't see any 1kV images and don't quite understand what you mean by
referring to a "strange superficial structure".
Another point is the presence of F. The fact that the software shows it
DOES NOT mean it's there (and the actual spectrum you provided doesn't
tell it's there).
Regards,
Vladimir
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Hernefjord Ingemar
Sent: Thursday, September 06, 2007 10:01 AM
To: [log in to unmask]
Subject: [TN] Semi guys, need support
25 micron gold ball bonding bad yield, ball lifts, poor adhesion on Al
pads. Triple diff line tranceiver chip. Weird micrographic exteriour,
EDAX gives C,F,O, Cl,Cu,Al,Fe. Cu can be ppm alloy but the others
unwanted on semi chip bond pads I think. 1kV SEI SEM reveals strange
superficial structure. Chip not contaminated by us, fresh opened chip
trays show this face. Question: what semi manufacturing problem can this
be? Will post a few pics to Steve's gallery.
TrikeMan?
/Inge
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|