Hi Jon - the minimum solderability coverage required by the JSTD-002 is 95%
and if a component vendor is not willing to sign up for that requirement,
it means they are not confident that their plating chemistry and/or plating
process can achieve the 95% minimum value. You need to determine if by
accepting a lower minimum value, such as the 90% figure, you will or will
not impact your soldering process workmanship requirements or solder joint
integrity. Good Luck.
Dave Hillman
JSTD-002 Committee Chair
[log in to unmask]
Jon Roberts
<jroberts@DRS-TEM
.COM> To
Sent by: TechNet [log in to unmask]
<[log in to unmask]> cc
Subject
01/18/2007 04:12 [TN] MATTE TIN AND SOLDERABLILITY
PM REQUIREMENTS
Please respond to
TechNet E-Mail
Forum
<[log in to unmask]>
; Please respond
to
Jon Roberts
<jroberts@DRS-TEM
.COM>
Has anyone have Knowledge on solderablity of matte tin finish on
components?
Question came up today from an vendor of the component being purchased
will only guarantee 90% coverage in lieu of J-Std-002 95% coverage and has
requested relief from the J-Std-002 requirement.
Thanks, Jon
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|