Rich: We have used Loncoterge MACH 73 for many years. With that said
Loncoterge was a product of the London Chemical Company(LONCO) which was
bought out years ago by Cookson Electronics as part of there Alpha
Metals group.
They may still carry it in a re-branded form.
Basically it is a 50% aqueous solution of Glycolic Acid . We take it as
received and dilute that by 15:1, water to Loncoterge. Close outgoing
drain valves. Fill all tanks, prewash/wash/rinse1/rinse2/rinse3/etc with
water and Loncoterge, heat to 130F. Circulate one hour. Open valves and
drain. Rinse entire system with fresh DI water twice at 140F for 15 mins
each. If using saponifier charge at half strength, circulate at standard
operating temperature for 15 mins, drain and recharge system for
operation.
It's also good practice to replace any core/tube/bag filters. Check
nozzle output for clogging, spray pattern and angle.
Regards
Michael Barmuta
Staff Engineer
Fluke Corp.
Everett WA
425-446-6076
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Richard Kraszewski
Sent: Tuesday, January 09, 2007 9:24 AM
To: [log in to unmask]
Subject: [TN] Descaling of Water Wash Systems
To ~continue along this forum's recent cleaning track...
What are you using for de-scaling water wash systems?
Any recommendations would be appreciated.
Rich K / GTS
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
This message (including any attachments) contains confidential
and/or proprietary information intended only for the addressee.
Any unauthorized disclosure, copying, distribution or reliance on
the contents of this information is strictly prohibited and may
constitute a violation of law. If you are not the intended
recipient, please notify the sender immediately by responding to
this e-mail, and delete the message from your system. If you
have any questions about this e-mail please notify the sender
immediately.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|