Vladimir,
You are right, it is just that I had this problem too and in the end the
conductors had cracks and the pads were really lifted-(not ground pads
solder mask defined)..I could see the cracks only by X-ray...
Gaby
----- Original Message -----
From: "Vladimir Igoshev" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, November 17, 2006 7:06 PM
Subject: Re: [TN] One solder Ball Not Connected on a No Connect Pad After
Rework


> Hi Gaby,
>
> It doesn't have to be cracked, particularly if the pad in question is
> non- SMD.
>
> Regards,
>
> Vladimir
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Gabriela Bogdan
> Sent: Friday, November 17, 2006 10:56 AM
> To: [log in to unmask]
> Subject: Re: [TN] One solder Ball Not Connected on a No Connect Pad
> After Rework
>
> If the pad comes off it is because there is a crack between the pad and
> the
> base material, and no conductor is there to prevent it from coming off.
> I
> would suspect that if you do a cross section of active pads in the same
> area
> you have a fair chance to see such cracks unde the pads, and even lifted
> pads.
> You intend to  replace the BGA on this area. Are you sure that the new
> connections will be as good as new?
> Gaby
> ----- Original Message -----
> From: "bob wettermann" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Friday, November 17, 2006 6:10 PM
> Subject: [TN] One solder Ball Not Connected on a No Connect Pad After
> Rework
>
>
>> This question to the group is about expected solder joint strength on
> a
>> BGA.
>>
>>  The BGA in question is a 8 x 8mm plastic package  BGA using a LF
> SAC305
>> soldering process. It has 64  x 0.018" balls holding it to  the PCB.
>>
>>  When removing this device for rework 3-4% of the time one of the
> corner
>> NO CONNECT pads comes off.
>>
>>  The question is if we do nothing upon replacement of  a new device
> to
>> the damaged pad will it really make a difference ??? We are arguing
> that
>> the holding strength of the reworked device would be approximately
> the
>> same because the change in overall surface area is marginally
> impacted.
>>
>>
>>  Thanks
>>
>>  Bob Wettermann
>>
>>
>> Bob Wettermann
>>
>> ---------------------------------------------------
>> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>> To unsubscribe, send a message to [log in to unmask] with following text
> in
>> the BODY (NOT the subject field): SIGNOFF Technet
>> To temporarily halt or (re-start) delivery of Technet send e-mail to
>> [log in to unmask]: SET Technet NOMAIL or (MAIL)
>> To receive ONE mailing per day of all the posts: send e-mail to
>> [log in to unmask]: SET Technet Digest
>> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
>> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
>> for additional information, or contact Keach Sasamori at
> [log in to unmask] or
>> 847-615-7100 ext.2815
>> -----------------------------------------------------
>> PH 847-767-5745
>>
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text
> in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives
> Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
> ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2