Hi Roland,
There was some work done by IBM [I think in Minneapolis] in the late 80's. I
showed that a full barrel crack needed to have at least a 90% physical
separation before a significant resistance increase could be measured. That is why
testing for barrel cracks is done in situ, or after the test a some elevated
temperature. At room temperature barrel cracks are essentially electrically
invisible; perhaps signal degradation could be found with high-frequency signals.

Werner

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2