Subject: | |
From: | |
Reply To: | |
Date: | Mon, 23 Jan 2006 09:59:33 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
be careful what you wish for: (a) if you use reliability test chamber, your
QA will kill you (can't clean it up enough to next rel test). (b) if you
use accelerated cure, some of RTV will be extra hard compare to the room
temp 7 day process... what ever you qualed before, may not be valid if you
change the cure procedure.
jk
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Kevin Glidden
Sent: Monday, January 23, 2006 9:40 AM
To: [log in to unmask]
Subject: [TN] Humidity Cure Chambers
Hi all,
Does anyone know where I can look for simple humidity chambers for curing
moisture-cure RTV? My searches yield all programmable, temperature /
humidity chambers, which is a little overkill for what I need. All I need
is steady-state humidity @ 50% RH with only slight warming above room
temperature - 80F or so. We are currently using a wooden box with a light
bulb or two and a bowl of water. Doesn't seem like the best solution, but
perhaps it is?
Thanks in advance,
Kevin
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|