        I believe that it is allowed. What is now allowed is cuts into the material, such as one done by holding a lead with a narrow tip pliers while forming it. 
        Regards,
        Ramon

-----Original Message-----
From: Connie Korth [mailto:[log in to unmask]]
Sent: Thursday, March 10, 2005 12:56 PM
To: Dehoyos, Ramon
Subject: RE: [TN] Lead deformation


It just depressed the lead maybe 40%(?).  There is no cut in the lead.

-----Original Message-----
From:   Dehoyos, Ramon [SMTP:[log in to unmask]]
Sent:   Thursday, March 10, 2005 11:51 AM
To:     [log in to unmask]
Subject:        RE: [TN] Lead deformation


           Hi Connie:
                        Is it flattened? or is it a cut into the lead?
           Regards,
           Ramon

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Connie Korth
Sent: Thursday, March 10, 2005 11:47 AM
To: [log in to unmask]
Subject: [TN] Lead deformation


        We received a capacitor with tool marks from forming the leads. 
 hem.
 There is no copper exposed, but the deformation exceeds 10% of the
diameter.  It doesn't make any difference how the defomation occurred to
determine whether it is a defect, does it?  I say it fails no matter what.

        Thoughts from anyone??

        Thanks,

        Connie M. Korth
        Quality Specialist
        Reptron Mfg. Services, Hibbing
        [log in to unmask]
        218.262.8209

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
for additional information, or contact Keach Sasamori at [log in to unmask] or 
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2