TECHNET Archives

October 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Bloomquist, Ken" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Bloomquist, Ken
Date:
Wed, 27 Oct 2004 10:14:06 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (44 lines)
Thank you everyone! I think from all your replies I have the answer. Our application would work with plating down to 15 microinches. That is well below the 30 that several of you have mentioned. With some additional testing at say 20 microinches I think we'll be OK.

Thanks again,

KennyB

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Valerie St.Cyr
Sent: Wednesday, October 27, 2004 8:38 AM
To: [log in to unmask]
Subject: Re: [TN] Gold Board


Ken,

Gold embrittlement is more a concern for fine pitch surface mount joints
where the percentage volume of gold grows as the absolute volume of paste
decreases. That being said, the gold thickness should still be kept low.
The pads which need to be gold will drive the final decision; why are
those pads gold and what does that mean for their necessary gold
thickness? If they are "thick" electrolytic gold, over 30 microinches,
then typically the fabricator would make the board in 2 gold passes: one
pass to put on a light sacrificial thickness of gold; then they would mask
off the whole board except for the pads of interest; then another pass in
gold to plate up those pads thicker - to 30 or 40 or 50 microinches
(whatever is called for). This 2 pass processing adds cost. If the gold
pads can be 25 microinches or less, then they can just gold plate the
whole board in one pass.

For all of this I am assuming that this is electrolytic gold over
electrolytic nickel.

Valerie

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2