Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Tue, 21 Jan 2003 13:16:52 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
We have had pretty good luck with Sypris in Kennesaw, GA for traceable
Hydrometer and other instrument calibration and standard recertification.
George Carroll
[log in to unmask]
-----Original Message-----
From: Larry Russell [mailto:[log in to unmask]]
Sent: Tuesday, January 21, 2003 12:20 AM
To: [log in to unmask]
Subject: [TN] Hydrometer calibrations
We would like to have any suggestions or information as follows:
1. How to calibrate our hydrometers, are there any other ways to calibrate
the hydrometers?
2. How do we measure the liquid lighter than water and liquid heavier than
water
3. Our hydrometers ranged from 0.600 to 1.800 with a number of 19 pieces
4. Is there any environment condition requirements to calibration
5. Can we use standard hydrometer to compare with others
we would greatly appreciate what you can provide us with valuable
information related to calibration of hydrometers
Thanks! Have a nice day!
sincerely
Jack Low
[log in to unmask]
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------
|
|
|