I may be mistaken, but I thought that some of the no-clean flux residues
were designed to accept conformal coating.  Perhaps your flux manufacturer
can shed some light...

Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879


        -----Original Message-----
        From:   Leland Woodall [SMTP:[log in to unmask]]
        Sent:   Wednesday, May 08, 2002 3:42 PM
        To:     [log in to unmask]
        Subject:        [TN] Cleaning of No-clean Assemblies

        Folks,

        We've been asked to investigate the pros and cons of performing an
aqueous
        wash of our no-clean assemblies prior to them receiving an acrylic
conformal
        coating.  Our management team wants the product to be absolutely
free from
        any type of contamination.

        Has anyone had any experience with this?  What are the possible
advantages
        and some of the pitfalls we could anticipate?

        Are there any knowledge sources that you might be able to recommend?

        Any assistance would be sincerely appreciated.

        Regards,

        Leland Woodall
        Quality Coordinator
        Keihin Carolina System Technology, Inc.
        4047 McNair Road
        Tarboro, NC 27886

        Phone:  252-212-1565, ext. 2865


----------------------------------------------------------------------------
-----
        Technet Mail List provided as a free service by IPC using LISTSERV
1.8d
        To unsubscribe, send a message to [log in to unmask] with following
text in
        the BODY (NOT the subject field): SIGNOFF Technet
        To temporarily halt delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL
        To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
        Search the archives of previous posts at:
http://listserv.ipc.org/archives
        Please visit IPC web site http://www.ipc.org/html/forum.htm for
additional
        information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315

----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2