Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Thu, 8 Nov 2001 17:04:00 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
1. e. all of the above.
I profile all these locations to ensure the desired temperature is
reached and to expose any unseen problem areas.
Use the clamp-on TC’s (Saunders from Datapaq) for everything except
buried in solder. (Kinda’ messy on expensive TC’s)
2. a.
3. a+b
I check the maximum temperature and duration for new components. In
developing my profile, I have considered this information. The target Time
Above Liquidus (TAL) is 60 seconds. The actual time may vary, based on
population, ramp rate (available soak time), necessary through-put,
complexity of the PCB AND the oven I am using. (short oven vs. long oven)
The TAL never exceeds 90 seconds
The manufacturers spec for the solder is also part of the profile
consideration.
Richard Elensky
Sr. Manufacturing Engineer
[log in to unmask]
Tel: 559-292-1111 x246
Fax: 559-292-9355
Dantel
2991 North Argyle Ave.
Fresno, CA, 93727
Visit our web site at:
http:// www.dantel.com
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|