Kathy
It is possible for SOME "no-clean" flux residues to sublimate over time
and then condense elsewhere in a sealed box. This is most likely if the
residues are in the warmest spot and the condensation in the coolest
spot.
Brian
> "Stillings, Kathy" wrote:
>
> A question for the experts...
>
> Is anyone using no-clean on hermetically sealed units? I am running
> into an issue with flux contamination on a few solder joints in a unit
> that contains MIMICs and wedge bonds and is hermetically sealed. The
> flux comes from a couple of magnet wire terminations in the unit. Can
> anyone share some insight?
---------------------------------------------------------------------------------