Jorge,

Au thickness of .1 or even .5 umeters is not sufficent to cause Au
embrittlement.  I agree with Phil, the initial gold-to-nickel interface or
Ni oxide may be the weak link, not gold embrittlement.

Regards,
Bruce Misner

> ----------
> From:         Jorge Rodriguez[SMTP:[log in to unmask]]
> Reply To:     TechNet E-Mail Forum.;[log in to unmask]
> Sent:         Wednesday, May 30, 2001 4:39 PM
> To:   [log in to unmask]
> Subject:      [TN] Gold embrittlement
>
> We have a SMT connector with leads that have a minimum of 0.1 micrometers
> of
> gold plating over 1.5 micrometers of nickel underneath. We don't know why
> the solder joint on this component, even though it looks OK,  breaks and
> fractures very easily. I suspect the gold is making the joint very brittle
> but I am not sure. We already checked the oven profile and it looks
> alright.
> From all the components this is the only one we are having problems with.
> Any advice?. Is there a solder paste that help when gold plated components
> are used?
>
>
> Any advice would be appreciated.
>
>
> Jorge Rodriguez
> Process Engineer
> Varian Electronics Manufacturing
> E-mail: [log in to unmask]
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2