You can measure the ionic contamaination levels. An Omegameter works well.
Jim Gilbert
-----Original Message-----
From: Poh Kong Hui [SMTP:[log in to unmask]]
Sent: Wednesday, May 31, 2000 10:56 AM
To: [log in to unmask]
Subject: [TN] Measurement of flux residue
Hi all Technetters,
I would like to know is there any way to measure the flux
residue that left on the board, after wave-soldering process.
Thanks in advance.
Regards,
Poh
##############################################################