John
Assuming your product is commercial in nature, I would suggest you have a
innerlayer registration requirement. I am aware of several very expensive
fires (taking out entire facilities) that were caused by poor innerlayer
registration and voltage surges. After incorporating the so called R coupon
and enforcing the test the issue was resolved
----- Original Message -----
From: "Murphy, John" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Monday, April 07, 2008 1:13 PM
Subject: [TN] layer to layer registration?
Greetings,
Is it a good idea to specify layer to layer
registration for Class II
multi-layer PCB's? My searching thus far indicates it is not directly
contained
in any IPC specification (other than annular ring requirements) but
relegated to
the Master Drawing.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|