Kevin,
I am unfamiliar with the smoking requirement you mention. Can you expand
on the need? Is it smoking during soldering or during some other step?
Regards,
Bob Metcalf
Western Regional Manager
Atotech USA Inc
1750 Overview Drive
Rock Hill, South Carolina 29730 USA
Mobile: 714-334-7667
e-mail: [log in to unmask]
Internet: www.atotech.com
Managing Director: Kuldip Johal
This e-mail and any attachments hereto are business documents of Atotech
USA Inc. and may contain CONFIDENTIAL OR PROPRIETARY BUSINESS INFORMATION.
Unauthorized disclosure and/or use of information contained in this
e-mail are prohibited. If you are not the intended recipient, you should
dispose of it and not use, disseminate or copy this message or any other
files transmitted with it.
.
From: "Glidden, Kevin" <[log in to unmask]>
To: <[log in to unmask]>
Date: 10/06/2011 06:40 AM
Subject: [TN] Soldermask recommendation
Sent by: TechNet <[log in to unmask]>
Good Morning,
We have a need to pass flammability, smoke, and toxicity testing for some
products. PCB soldermask has been identified as one of the key
contributors to the smoking. Does anyone know of a PCB soldermask that
is UL94V0 but also low smoke generating? The two criteria are seemingly
at odds, since the halides that create the non flammability also make the
smoke...
Thanks for the help!
Kevin
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 16.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|