Hi Dave:   We are installing SMD's on an FR-4 palletized scored array.  
It is 6-up, each 1.0" wide by 11.5" in length.  Material Thickness is
.042" and I specified scoring depth to leave .015" material.  Have been 
doing approx. 500 assemblies every 7 weeks for approx. 2.5 years.  Found 
the trick to scoring is depth and parallelism of top and bottom V-cuts.

Hope this helps!

Bill Black
Medco
 

***************************************************************************