Subject: | |
From: | |
Date: | Mon, 9 Dec 96 11:51:20 PST |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Andy,
A variety of methods exist for creating blind vias. Generally speaking, the
most cost effective options are microvia technologies. Technologies such as
photovias and plasma technologies are generally more cost effective than
controlled depth drilling. Lasers are also an option to mechanical drilling.
Plasma and photovia blind vias are mass produced -- the cost of 50,000 blind
vias from layer 1 to 2 and n to n-1 are the same as the cost of one microvia.
Merix produces blind microvias using a plasma process known as DYCOstrate. I
would be happy to discuss this technology further or send you more information
about the process if you are interested.
John Stewart
email: [log in to unmask]
phone: 503.359.2674
fax: 503.357.1234
www: www.merix.com
"Andrew Buonviri"<[log in to unmask]> Wrote:
|
|
|
|
|
| My company is looking to design a multilayer PCB with blind vias.
| Another
| company will do the actual fab. I've heard there's more than one
| way to
| do blind vias: either controlled depth drilling or fabbing and
| drilling
| two halves of a board separately and sticking them together. Does
| anyone
| have any experience with either of these methods, and is there
| another
| way I don't know of? Which way is better, what are the risks, etc?
| Any
| info would be appreciated. Thanks,
| Andy Buonviri
| Ixthos, Inc.
| [log in to unmask]
|
|
| ********************************************************************
| *******
| * TechNet mail list is provided as a service by IPC using SmartList
| v3.05 *
| ********************************************************************
| *******
| * To unsubscribe from this list at any time, send a message to:
| *
| * [log in to unmask] with <subject: unsubscribe> and no text.
| *
| ********************************************************************
| *******
| * If you are having a problem with the IPC TechNet forum please
| contact *
| * Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]
| *
| ********************************************************************
| *******
|
|
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|