Subject: | |
From: | |
Reply To: | |
Date: | Tue, 16 Nov 2004 09:39:52 EST |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi Bill,
The immediate fix is to make the pads larger. The real problem is a larger
CTE mismatch between the SOD323 and the PCB, and thoise leads do not even
deserve to be called leads--zero compliancy. These 'leads' need to be turned UNDER
the component body to decrease the DNP.
BUT, neither of these steps assures a solution--it may simply move the
failure mode from ripped-out pads to fractured solder attachments.
The real solution is to turn the component upside-down and provide it with
longer compliant leads; no sacrifice in real estate..
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives