TECHNET Archives

October 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show HTML Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Randy Bock Sr." <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Fri, 11 Oct 2002 12:35:15 -0400
Content-Type:
multipart/alternative
Parts/Attachments:
text/plain (4 kB) , text/html (6 kB)
RE: [TN] Clean room.Sticky floor mats at the entrances also helps a lot form dirty on the bottom of your feet.  You track in
tons of dirt on the bottoms of you shoes.  Especially crape sole shoes, sneakers.


  ----- Original Message ----- 
  From: Brummer Chuck 
  To: [log in to unmask] 
  Sent: Friday, October 11, 2002 10:54 AM
  Subject: Re: [TN] Clean room.


  How "not clean enough" are you.  We are producing 1 mil lines and spaces in a class 10,000 clean room.  Several parts of this clean room are not really correct but it works.  (the vinyl tile floor is not cleanroom adequate)  At my last job, many years ago, I created a "clean space"  by cutting off traffic, improving filtering (but not to the HEPA level) and putting the operators in smocks and bouffant.  Just creating a clean attitude is the 60% of the battle.  If your operators have not worked in a clean environment then you will have more training to do than construction.

  Chuck Brummer 
  Siemens 
  Canoga Park, California 
  (818) 734-4930 

  -----Original Message----- 
  From: Mike Holst. [mailto:[log in to unmask]] 
  Sent: Friday, October 11, 2002 3:54 AM 
  To: [log in to unmask] 
  Subject: [TN] Clean room. 



  Good day Technet community, 

  I would like to draw on the experience of those in pcb fabrication 
  and ask for opinions or advice regarding the need for clean working 
  areas in the pcb shop. 

  Our laser plotter / phototool production area and photoresist 
  lamination / exposure operations have been identified as 'not clean 
  enough' to reliably produce 4 mil lines and spaces. We do OK 
  down to 5 mils. 

  These areas are already 'nominally' clean but separate 
  departments and the plan is to intergrate them into a single 
  upgraded operation in a new location. 

  If it is advised that this should to be made a classifiable clean 
  room, what Class level are we talking about? If not, how clean is 
  clean enough? 

  Mike Holst. 





  Mike Holst. 
  TraX Interconnect (Pty) Ltd 
  Tel:(++27 21)712 5011 
  Fax:(++27 21)712 5798 
  Cape Town 
  South Africa 

  --------------------------------------------------------------------------------- 
  Technet Mail List provided as a free service by IPC using LISTSERV 1.8e 
  To unsubscribe, send a message to [log in to unmask] with following text in 
  the BODY (NOT the subject field): SIGNOFF Technet 
  To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) 
  To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest 
  Search the archives of previous posts at: http://listserv.ipc.org/archives 
  Please visit IPC web site http://www.ipc.org/html/forum.htm for additional 
  information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 
  --------------------------------------------------------------------------------- 

  --------------------------------------------------------------------------------- Technet Mail List provided as a free service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/html/forum.htm for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315 --------------------------------------------------------------------------------- 

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------


ATOM RSS1 RSS2